The current Zone Type setting is shown on the bottom line. To change a zone type, use the arrow keys to scroll through the list
of zone types then press ' # ' to select a new type. The display shows:
SELECT TYPE: 1
PERIMETER ×
ZONE RESPONSE TIME
All zones, in the Aegis 1000 are set to 300 milliseconds fixed response time.
ZONE TYPES
ZONE TYPE NUMBER DESCRIPTION
ENTRY/EXIT 0 Entry/Exit
PERIMETER 1 Perimeter
NIGHT INT 2 Night Interior
AWAY INT 3 Away Interior
2X ENTRY DELAY 4 Double Entry Delay
4X ENTRY DELAY 5 Quadruple Entry Delay
LATCH PERIM 6 Latching Perimeter
LATCH NIGHT INT 7 Latching Night Interior
LATCH AWAY INT 8 Latching Away Interior
PANIC 16 Panic
POLICE EMERG 17 Police Emergency
SILENT DURESS 18 Duress
TAMPER 19 Tamper
LATCH TAMPER 20 Latching Tamper
FIRE 32 Fire
FIRE EMERG 33 Fire Emergency
GAS 34 Gas Alarm
AUX EMERG 48 Auxiliary Emergency
TROUBLE 49 Trouble
FREEZE 54 Freeze
WATER 55 Water
FIRE TAMPER 56 Fire Tamper
AUXILIARY 64 Auxiliary
KEY SWITCH 65 Keyswitch Input
ENERGY SAVER 80 Programmable Energy Saver Module
OUTDOOR TMP 81 Outdoor Temperature
TEMPERATURE 82 Temperature
TEMP ALARM 83 Temperature Alarm
LATCHING ZONE TYPES
LATCHING ZONE TYPES ignore the status of that zone during power cycles.
If the FIRE ALARM VERIFICATION feature is being used, any device (other then FIRE or GAS) connected to an output
configured as a Switched Output (i.e. Glassbreak Detectors), must be connected to a zone configured as a LATCHING ZONE
TYPE (latching perimeter, latching night interior, latching away interior, and latching tamper).
DESCRIPTION OF ZONE TYPES
ENTRY/EXIT
ENTRY/EXIT ZONE types are intended for doors. ENTRY/EXIT ZONES are armed in security modes DAY, NIGHT, AWAY,
and VACATION. In DAY and AWAY modes, there is an entry delay (defined by ENTRY DELAY) on ENTRY/EXIT ZONES
to allow you to get into the house and turn off the alarm before it sounds. In NIGHT & DAY INSTANT mode, there is no entry
delay, so that the alarm sounds immediately if someone opens a door.