3/1 FORMAT
Older central stations may require a 3/1 format. To use 3/1 format, both account numbers must be changed to 3 digit codes and
EVERY alarm code must be changed to a 1-digit code. Do not mix code lengths!
OPENING AND CLOSING REPORTS
The Aegis 1000 system can send opening and closing reports by user to the central station.
When the system is disarmed by user code 1-8, the communicator can call the central station and report that the system was
disarmed (opened) with the user code that was used.
When the system is armed by user code 1-8, the communicator can call the central station and report that the system was armed
(closed) with the user code that was used.
If the system is disarmed by any other method other than one that requires a user code (i.e. Keyswitch or Scheduled Program), the
communicator will send a generic OPEN report to the central station. The code that is sent is defined as OTHER OPEN. If the
system is armed by any other method other than one that requires a code (i.e. Quick Arm, Keyswitch, or Scheduled Program), the
communicator will send a generic CLOSE report to the central station. The code that is sent is defined as OTHER CLOSE.
DEFAULT REPORTING CODES FOR 4/2 FORMAT
CODE ZONE CODE ZONE
98 TEST CODE 81 FREEZE ALARM
01 ZONE 1 82 FIRE EMERG
02 ZONE 2 83 POLICE EMERG
03 ZONE 3 84 AUX EMERG
04 ZONE 4 85 DURESS ALARM
05 ZONE 5 86 BATTERY LOW
06 ZONE 6 87 FIRE ZN TRBL
07 ZONE 7 99 CANCEL
08 ZONE 8 40 OTHER OPEN
09 ZONE 9 41 USER 1 OPEN
10 ZONE 10 42 USER 2 OPEN
11 ZONE 11 43 USER 3 OPEN
12 ZONE 12 44 USER 4 OPEN
13 ZONE 13 45 USER 5 OPEN
14 ZONE 14 46 USER 6 OPEN
15 ZONE 15 47 USER 7 OPEN
16 ZONE 16 48 USER 8 OPEN
17 ZONE 17 60 OTHER CLOSE
18 ZONE 18 61 USER 1 CLOSE
19 ZONE 19 62 USER 2 CLOSE
20 ZONE 20 63 USER 3 CLOSE
21 ZONE 21 64 USER 4 CLOSE
22 ZONE 22 65 USER 5 CLOSE
23 ZONE 23 66 USER 6 CLOSE
24 ZONE 24 67 USER 7 CLOSE
25 ZONE 25 68 USER 8 CLOSE